Aubrey Chimney Contractors

What Your Fireplace Is Doing When It Burns

What Is the Fireplace Doing?

Scope of the Job

This visit stays at the hearth. On a gas unit we open the lower access panel, look at the valve, pilot assembly and burner, check the glass gasket and test the fittings for leaks. On a wood fireplace we check the firebox walls, damper and hearth extension. On both we measure how close the mantel and trim sit to the opening. You get a list of findings with photos.

Access panel opened, valve area viewed
Glass seal and frame looked over
Firebox panels or brick checked for cracks
Distance to mantel and trim measured
Hearth extension size and condition

The parts we look at on a gas fireplace

A gas fireplace has more working parts than people expect. Gas arrives through a shutoff, often a key in the floor beside the hearth or a valve behind the lower grille. It reaches a control valve, which only lets gas through to the burner when a safety device tells it the pilot is lit. On many older units that safety device is a thermocouple, a little sensor heated by the pilot flame that produces just enough electricity to hold the valve open. Newer units use a flame sensor and an electronic module. From the valve, gas goes to the burner, a pan or tube with ports that spread the flame under the logs or across a bed of glass. Above it all sits the vent, whether that is an old brick flue, a metal pipe, or a pair of pipes through the wall on a direct vent unit. Our inspection checks each of these in turn, from the shutoff to the outside end of the vent.

With the unit running we look at the flame. A healthy gas flame on a log set is mostly blue at the base with soft yellow tips; a tall lazy orange flame, black tips or soot marks on the logs mean the air mix or the log layout is off. We take a carbon monoxide reading in the room beside the fireplace and at the opening, since a vent that is not drawing properly sends exhaust back toward you. On sealed units we check the glass for cracks and the gasket around it, because the glass is part of what keeps exhaust out of the room. On units with a standing pilot we check that it lights cleanly and holds. Any gas smell at the valve or joints is tested with a leak detector. The report lists what was fine, what needs attention and what should stop use until fixed.

Wood fireplaces, and when to go past the room

On a wood-burning masonry fireplace the room side is simpler but still worth a careful look. The firebox walls are lined with firebrick, a dense brick made to take direct flame; we look for cracked faces and missing joints, since gaps let heat into the ordinary brick and framing behind. The damper should open fully and close fully, and its handle should hold a position. Out front, the hearth slab that stops stray embers must be intact and extend far enough past each side of the opening. Mantels and wood trim should sit far enough from the fire that they never get more than warm. Glass doors should seal and their frames should not rattle. Many older homes in La Habra and Fullerton have a wood box with a gas starter pipe running through it, which we check as a gas appliance in its own right.

A fireplace inspection does not climb the roof or put a camera up the flue. When what we see in the room suggests a problem above it, such as tile fragments on the smoke shelf, a white condensation crust or soot staining the face above the opening, the report says the next step is a chimney inspection, and which level. Inspection visits start at $160, and a Level 2 with a video scan of the flue is $385. For homes changing hands, sellers and buyers often book the room inspection and the chimney inspection together, so the report covers the whole system from the gas key to the cap. Book through the contact page and tell us what the fireplace burns, how old the house is if you know, and whether anything about the fire has changed lately.

How Aubrey Chimney Contractors Works

Price on Paper

You approve a written figure before anything is ordered

Metered Diagnosis

Pilot circuits and gas pressure measured, not guessed

Leak-Tested Joints

Every gas fitting we touch is checked before we leave

Photos and Notes

A record of what we found and what we changed

Related Jobs

Chimney Sweep

Soot, creosote and nesting debris cleared from wood and gas flues, so exhaust can climb out the way the appliance expects.

Open →

Chimney Inspection

Level 1 or Level 2 under NFPA 211, read with gas appliances in mind: vent size, connector, termination and clearances.

Open →

Chimney Repair

Brick, mortar, crown, liner and firebox repairs, planned around any gas line or vent that shares the chimney.

Open →

Fireplace Repair

Cracked firebrick, worn refractory panels, sticking dampers and dropped hearths repaired, on masonry and factory-built fireplaces alike.

Open →

Chimney Level 2 Inspection

Video through each flue plus the attic and roof run, for a sale, a switch to gas, or after a chimney fire or quake.

Open →

Chimney Cap Installation

Caps with spark screen fitted over one flue or several, and listed tops on factory-built gas vents replaced with the matching part.

Open →

Chimney Flashing Repair

Step and counter flashing renewed where the roof meets the chimney or a gas vent pipe, with a cricket where water pools.

Open →

Chimney Masonry Repair

Spalled brick replaced and open joints repacked with a mix that matches the brick, before water and heat do more harm.

Open →

Chimney Rebuilds

Chimney tops rebuilt from solid brick upward, or replaced with a framed chase and metal vent that suits a gas appliance.

Open →

Fireplace Cleaning

Ash, soot and glass film removed from wood and gas fireplaces, with doors, screens and the hearth face cleaned and the room kept covered.

Open →

Gas Fireplace Cleaning

Burner ports, pilot hood, logs and the inside of the glass cleaned, so the flame sits blue at its base and the glass clears.

Open →

Gas Fireplace Repair

Pilots that drop out, igniters that spark without lighting, weak thermocouples, failed valves and dead remotes traced with a meter and fixed.

Open →

Fireplace Remodel

New mantels, surrounds and hearths fitted around wood or gas fireboxes, with distances to the opening kept within the unit's listing.

Open →

Fireplace Inserts

Gas inserts set into an existing firebox with their own vent to the top, sized for the room and the opening.

Open →

Pellet Stove Repair

Repairs to stoves that burn pellets: a jammed auger, a cold igniter, a noisy fan or a board that throws codes, plus the vent.

Open →

Wood Stove Repair

Door gaskets, baffles, firebrick, glass and air controls on wood stoves renewed, with the stovepipe and clearances checked.

Open →

Gas Logs

Gas log sets fitted in a wood fireplace, with the burner size, flue and room checked before the line is run.

Open →

Chimney Seismic Retrofit

Old brick stacks braced, strapped to the framing or cut down under a light chase, so a quake is less likely to drop them.

Open →

Chimney Crown Repair

Cracked or crumbling crowns sealed or reformed with pitch and an overhang, so rain sheds away from the brick below.

Open →

Dryer Vent Cleaning

Lint packed in dryer ducts cleared from the outside hood back to the machine, so the dryer runs cooler and finishes loads sooner.

Open →

Chimney Liner Installation

Stainless liners sized for the gas or wood appliance they serve, run inside a flue whose clay tile is cracked or oversized.

Open →

Chimney Leak Repair

Water coming in at the chimney traced to the crown, cap, flashing, brick or vent boot, then stopped at that source.

Open →

Chimney Waterproofing

A breathable repellent applied to sound brick, so less rain soaks in while damp inside the wall can still dry out.

Open →

Chimney Damper Repair

Throat dampers that stick, warp or never seal freed or replaced, or a top-sealing unit fitted with a pull cable.

Open →

Chimney Chase Cover

Rusted or sagging steel lids on framed chimneys replaced with a custom pitched lid and a fresh seal at the vent pipe.

Open →
Book a Visit