A Damper That Works With Your Gas Logs, Not Against Them
What Is the Fireplace Doing?
Gas or wood, the make if you know it, and the symptom. A technician from Brea follows up to set a time.
Scope of the Job
A damper that will not seal lets warm air leave the house all winter, and a rusted plate may not move at all. We free plates rusted in place, replace bent handles and warped frames, or fit a top-sealing unit worked by a cable when the throat cannot be saved. Where gas logs are installed, a stop holds the plate open by the distance the burner needs.
What a damper does, and what goes wrong
Just above the opening of most masonry fireplaces, in the narrow throat where the firebox meets the flue, sits a cast iron or steel plate on a pivot, worked by a handle, a lever or a rotating knob. Open, it lets smoke and exhaust up. Closed, it keeps warm room air in and cold outside air out. In homes around Brea the damper is often the most neglected part of the fireplace, because it lives out of sight in a hot, sooty, sometimes damp spot. A flue with no cap lets storms rust the plate. Heat warps the plate so it no longer sits flat. The pivot seizes, the handle linkage loosens or falls apart, and the frame it closes against can crack. Seized closed, it turns smoke or burner exhaust back on the room; jammed ajar, it leaks heat every month of the year.
On a gas hearth the damper carries one more job. A vented gas log set must have the damper fixed open while the logs are installed, because the logs make exhaust that has to leave through the flue and there is no smoke to warn anyone that a closed damper is causing trouble. The usual answer is a clamp, a simple metal stop fitted so the damper cannot shut fully. We see plenty of log sets in Fullerton and La Habra installed without one, and plenty of clamps removed by an owner who wanted to stop a draft. Both are worth fixing. On sealed gas inserts the old damper is usually removed or fixed open during installation so the liners can pass, and checking that it was done properly is part of the visit.
Repair, replace or move it to the top
Many dampers can be freed and adjusted. A seized pivot can be cleaned and worked loose, a bent plate can sometimes be straightened, and a broken handle or linkage can be rebuilt. When the plate is rusted through or the frame is cracked, a fresh plate and frame can go into the throat, though fitting it can mean some masonry work in a tight space. The other route is a damper at the top of the chimney. It sits on the crown under its own lid, pulled down onto a rubber seal by a spring, and worked from below by a stainless line hooked to a bracket on the firebox wall. Closing the flue at the crown, it doubles as a lid against storms and nesting birds. Top dampers suit wood fireplaces well; over a vented gas log set the damper must be locked open, so a top damper there would have to be fixed open too.
The written quote names the damper we found, what is wrong with it, and the options that fit your fireplace and how you use it, each with its own figure. A repair to the existing damper is usually the cheapest; a new throat damper or a top damper costs more and each has trade-offs we explain in plain words. If the flue above needs a cap, the cap is quoted after we measure, though a top damper can take its place on a wood fireplace. If a gas log set is involved, the clamp is part of the quote. To book, use the contact page and tell us what happens when you work the handle, whether the fireplace burns wood or gas, and whether you notice a draft or smoke in the room.
How Aubrey Chimney Contractors Works
Price on Paper
You approve a written figure before anything is ordered
Metered Diagnosis
Pilot circuits and gas pressure measured, not guessed
Leak-Tested Joints
Every gas fitting we touch is checked before we leave
Photos and Notes
A record of what we found and what we changed
Where we offer chimney damper repair
Brea, La Habra, Fullerton and Anaheim carry their own pages for this job, with postcodes, homes and weather notes. Search below for any other city.
Nothing on our list by that name. Type the closest larger city instead, or use the contact form.
Related Jobs
Chimney Sweep
Soot, creosote and nesting debris cleared from wood and gas flues, so exhaust can climb out the way the appliance expects.
Open →Chimney Inspection
Level 1 or Level 2 under NFPA 211, read with gas appliances in mind: vent size, connector, termination and clearances.
Open →Chimney Repair
Brick, mortar, crown, liner and firebox repairs, planned around any gas line or vent that shares the chimney.
Open →Fireplace Inspection
Firebox, hearth, glass front, valve compartment and surround checked for heat wear, gas odor, tired gaskets and tight clearances.
Open →Fireplace Repair
Cracked firebrick, worn refractory panels, sticking dampers and dropped hearths repaired, on masonry and factory-built fireplaces alike.
Open →Chimney Level 2 Inspection
Video through each flue plus the attic and roof run, for a sale, a switch to gas, or after a chimney fire or quake.
Open →Chimney Cap Installation
Caps with spark screen fitted over one flue or several, and listed tops on factory-built gas vents replaced with the matching part.
Open →Chimney Flashing Repair
Step and counter flashing renewed where the roof meets the chimney or a gas vent pipe, with a cricket where water pools.
Open →Chimney Masonry Repair
Spalled brick replaced and open joints repacked with a mix that matches the brick, before water and heat do more harm.
Open →Chimney Rebuilds
Chimney tops rebuilt from solid brick upward, or replaced with a framed chase and metal vent that suits a gas appliance.
Open →Fireplace Cleaning
Ash, soot and glass film removed from wood and gas fireplaces, with doors, screens and the hearth face cleaned and the room kept covered.
Open →Gas Fireplace Cleaning
Burner ports, pilot hood, logs and the inside of the glass cleaned, so the flame sits blue at its base and the glass clears.
Open →Gas Fireplace Repair
Pilots that drop out, igniters that spark without lighting, weak thermocouples, failed valves and dead remotes traced with a meter and fixed.
Open →Fireplace Remodel
New mantels, surrounds and hearths fitted around wood or gas fireboxes, with distances to the opening kept within the unit's listing.
Open →Fireplace Inserts
Gas inserts set into an existing firebox with their own vent to the top, sized for the room and the opening.
Open →Pellet Stove Repair
Repairs to stoves that burn pellets: a jammed auger, a cold igniter, a noisy fan or a board that throws codes, plus the vent.
Open →Wood Stove Repair
Door gaskets, baffles, firebrick, glass and air controls on wood stoves renewed, with the stovepipe and clearances checked.
Open →Gas Logs
Gas log sets fitted in a wood fireplace, with the burner size, flue and room checked before the line is run.
Open →Chimney Seismic Retrofit
Old brick stacks braced, strapped to the framing or cut down under a light chase, so a quake is less likely to drop them.
Open →Chimney Crown Repair
Cracked or crumbling crowns sealed or reformed with pitch and an overhang, so rain sheds away from the brick below.
Open →Dryer Vent Cleaning
Lint packed in dryer ducts cleared from the outside hood back to the machine, so the dryer runs cooler and finishes loads sooner.
Open →Chimney Liner Installation
Stainless liners sized for the gas or wood appliance they serve, run inside a flue whose clay tile is cracked or oversized.
Open →Chimney Leak Repair
Water coming in at the chimney traced to the crown, cap, flashing, brick or vent boot, then stopped at that source.
Open →Chimney Waterproofing
A breathable repellent applied to sound brick, so less rain soaks in while damp inside the wall can still dry out.
Open →Chimney Chase Cover
Rusted or sagging steel lids on framed chimneys replaced with a custom pitched lid and a fresh seal at the vent pipe.
Open →