What Is the Fireplace Doing?
Gas or wood, the make if you know it, and the symptom. A technician from Brea follows up to set a time.
Scope of the Job
Lint builds up in the duct behind a dryer, and a gas dryer needs a clear path out just as a gas fireplace does. When the duct clogs, loads take longer, the cabinet heats up and the exhaust has nowhere to go. We clean the run from the hood outside to the connection behind the machine, replace crushed foil hose with metal duct where needed and make sure the hood flap closes.
Why a clogged duct is a gas problem too
Every dryer pushes warm wet air and loose lint down a duct to a hood on an outside wall or the roof. A gas dryer adds one more thing to that air: the exhaust from its burner, carbon monoxide included. When lint builds up along the duct, the airflow drops. An electric dryer just runs longer and hotter. A gas dryer does that too, and on top of it the burner exhaust has a harder time getting out, so some of it can end up in the laundry room. Lint is also flammable, and a hot dryer pushing against a packed duct is a fire risk we take seriously. In houses around Brea, many laundry rooms sit in the middle of the house or in the garage, which means long duct runs with several turns, and long runs with turns collect lint faster than short straight ones.
The signs are easy to spot once you know them, and most owners have seen at least one without connecting it to the vent. Loads take two cycles to dry. The top of the dryer is hotter than you remember. The laundry room stays humid after a load. Outside, the hood flap barely lifts while the dryer runs, or there is lint caught around it. Some dryers show a vent warning on the display. On a gas dryer, a burnt or sharp smell in the laundry room is worth acting on promptly. Any one of them is reason enough to book. We bring the tools that reach the whole run, and on gas dryers we treat the duct as an exhaust vent, which is what it is, and check it with the same care we give any other gas vent in the house.
What the cleaning covers and what the quote names
We start at the dryer, moving it out enough to reach the connection without straining the gas line or the electrical plug. The transition duct, the short flexible piece behind the machine, is checked for crushing and kinks, since it is often the narrowest point in the run. The main duct is then cleaned along its whole length with rotating brushes and moving air, working toward the outside, and the lint is collected rather than blown into the yard. At the hood we clear the opening and make sure the flap swings freely. Then we reconnect, check the gas connector for leaks on a gas dryer, run the machine and feel for strong airflow at the hood. If the duct turns out to be the wrong material, such as foil or vinyl flex in a wall, or crushed in an attic, we note it.
Some ducts cannot be made right by cleaning. A run that is too long for the dryer, has too many elbows, or rises steeply to the roof will clog again quickly however well it is cleaned. A roof termination with a screen will catch lint and close itself off. Duct sections joined with screws that poke into the airflow snag lint on every pass. Where we find any of these, the written quote sets out what rerouting or replacing the duct would involve and what it costs, separately from the cleaning, so you can choose. Property managers with several units in Anaheim or Fullerton can book a building at a time. To book, tell us whether the dryer is gas or electric, roughly where the laundry is in the house, and whether the vent leaves through a wall, the roof or the floor.
How Aubrey Chimney Contractors Works
Price on Paper
You approve a written figure before anything is ordered
Metered Diagnosis
Pilot circuits and gas pressure measured, not guessed
Leak-Tested Joints
Every gas fitting we touch is checked before we leave
Photos and Notes
A record of what we found and what we changed
Where we offer dryer vent cleaning
Brea, La Habra, Fullerton and Anaheim carry their own pages for this job, with postcodes, homes and weather notes. Search below for any other city.
Nothing on our list by that name. Type the closest larger city instead, or use the contact form.
Related Jobs
Chimney Sweep
Soot, creosote and nesting debris cleared from wood and gas flues, so exhaust can climb out the way the appliance expects.
Open →Chimney Inspection
Level 1 or Level 2 under NFPA 211, read with gas appliances in mind: vent size, connector, termination and clearances.
Open →Chimney Repair
Brick, mortar, crown, liner and firebox repairs, planned around any gas line or vent that shares the chimney.
Open →Fireplace Inspection
Firebox, hearth, glass front, valve compartment and surround checked for heat wear, gas odor, tired gaskets and tight clearances.
Open →Fireplace Repair
Cracked firebrick, worn refractory panels, sticking dampers and dropped hearths repaired, on masonry and factory-built fireplaces alike.
Open →Chimney Level 2 Inspection
Video through each flue plus the attic and roof run, for a sale, a switch to gas, or after a chimney fire or quake.
Open →Chimney Cap Installation
Caps with spark screen fitted over one flue or several, and listed tops on factory-built gas vents replaced with the matching part.
Open →Chimney Flashing Repair
Step and counter flashing renewed where the roof meets the chimney or a gas vent pipe, with a cricket where water pools.
Open →Chimney Masonry Repair
Spalled brick replaced and open joints repacked with a mix that matches the brick, before water and heat do more harm.
Open →Chimney Rebuilds
Chimney tops rebuilt from solid brick upward, or replaced with a framed chase and metal vent that suits a gas appliance.
Open →Fireplace Cleaning
Ash, soot and glass film removed from wood and gas fireplaces, with doors, screens and the hearth face cleaned and the room kept covered.
Open →Gas Fireplace Cleaning
Burner ports, pilot hood, logs and the inside of the glass cleaned, so the flame sits blue at its base and the glass clears.
Open →Gas Fireplace Repair
Pilots that drop out, igniters that spark without lighting, weak thermocouples, failed valves and dead remotes traced with a meter and fixed.
Open →Fireplace Remodel
New mantels, surrounds and hearths fitted around wood or gas fireboxes, with distances to the opening kept within the unit's listing.
Open →Fireplace Inserts
Gas inserts set into an existing firebox with their own vent to the top, sized for the room and the opening.
Open →Pellet Stove Repair
Repairs to stoves that burn pellets: a jammed auger, a cold igniter, a noisy fan or a board that throws codes, plus the vent.
Open →Wood Stove Repair
Door gaskets, baffles, firebrick, glass and air controls on wood stoves renewed, with the stovepipe and clearances checked.
Open →Gas Logs
Gas log sets fitted in a wood fireplace, with the burner size, flue and room checked before the line is run.
Open →Chimney Seismic Retrofit
Old brick stacks braced, strapped to the framing or cut down under a light chase, so a quake is less likely to drop them.
Open →Chimney Crown Repair
Cracked or crumbling crowns sealed or reformed with pitch and an overhang, so rain sheds away from the brick below.
Open →Chimney Liner Installation
Stainless liners sized for the gas or wood appliance they serve, run inside a flue whose clay tile is cracked or oversized.
Open →Chimney Leak Repair
Water coming in at the chimney traced to the crown, cap, flashing, brick or vent boot, then stopped at that source.
Open →Chimney Waterproofing
A breathable repellent applied to sound brick, so less rain soaks in while damp inside the wall can still dry out.
Open →Chimney Damper Repair
Throat dampers that stick, warp or never seal freed or replaced, or a top-sealing unit fitted with a pull cable.
Open →Chimney Chase Cover
Rusted or sagging steel lids on framed chimneys replaced with a custom pitched lid and a fresh seal at the vent pipe.
Open →