Plan a building visit
List the property and a rough fireplace count, and we plan the route through the units.
The gas checklist for every unit
Each fireplace gets the same list, so records from one building to the next line up item for item.
Findings sort into three groups: shut off until repaired, repair before the cold months, and fine for now. The first group is rare, but it always sits at the top of the unit sheet.
- Pilot flame size, and whether it wraps the thermocouple or thermopile
- Millivolt reading on the pilot safety
- Leak check from the key valve to the burner
- Glass, gasket and latches on sealed units
- Burner ports, logs and ember bed
- Vent run and termination: joints, clearances, nests, rust
- Carbon monoxide reading with the burner lit
- Wall switch, remote or thermostat operation
Access and residents
We work through the property in the order you set. Most managers send a notice of entry and arrange keys or a staff escort. Occupied units are fine as long as we have entry and the hearth area is clear.
Tenants often switch a gas fireplace off at the valve for summer, or leave the pilot burning all year. We note the state we found each unit in and leave it the way the manager asks.
What the board or owner receives
One summary sheet for the property and a separate page for each fireplace, with photos, readings and findings. An insurer, a lender or the buyer of a single unit can be given that unit's page alone.
Part repairs on gas units are written up by part and model, unit by unit, so a board can approve a batch in one decision. Where a vent or chase is common area under the CC&Rs, the finding says which part it concerns so the board can assign it.
Priced per fireplace
Every fireplace on the property is charged at the same rate, whatever the size of the complex.
- Level 1 gas check, per fireplace
- $160
- Level 2 with vent camera, per fireplace
- $385
- Masonry flue sweep, for units that still burn wood
- from $410
Gas part repairs are written up per unit, by part and model, before any work begins.
Building and HOA questions
Do all units need a Level 2?
No. A Level 1 suits units in regular use with nothing changed. A Level 2 fits a unit after a sale, a vent problem, a leak from above or a replacement fireplace.
Can you relight pilots that residents have turned off?
Yes, after the leak check and with the manager's approval. A unit that fails a safety check is left off and marked in the report.
What happens if a unit has a gas leak?
The gas is shut off at that unit's valve, the manager hears about it while we are still on site, and the finding goes to the top of that unit's page.
Who is responsible for the fireplace in a condo?
That depends on the association's CC&Rs. Some treat the vent and chase as common area and the unit as the owner's. We list findings by part so the board can assign each one.
Can the owner of a single unit book directly?
Yes, at the same per fireplace rate, with the report sent to the owner and to the association if the owner wants.
Plan the gas checks for your property
Use the contact page with the property name and roughly how many gas fireplaces it has, and we come back with a visit plan and the per fireplace total.
Call (657) 233-4301