A Pellet Stove Fails Like an Appliance, So We Test It Like One
What Is the Fireplace Doing?
Gas or wood, the make if you know it, and the symptom. A technician from Brea follows up to set a time.
Scope of the Job
Pellet stoves depend on small electric parts. When one tires, the stove may not light, may smother itself in pellets or may switch off part way through a burn. We clean the stove first, since ash causes many faults, then test the igniter, auger motor, fans and safety switches and replace what failed with parts for that model. The vent is cleaned and its joints resealed.
Why a pellet stove stops, in parts
A pellet stove has more in common with the furnace in your garage than with a log fire. Pellets sit in a bin at the top or back. A screw turned by a slow motor, the auger, carries a measured stream of them down into a small cup called the burn pot. An electric igniter, much like a hair dryer element, heats air blown through the pot until the pellets catch. A blower then forces exhaust out through a small vent pipe, and a second fan sweeps household air over the heated firebox and returns it warm. Small probes track box heat and draft vacuum, and a circuit board decides what to do with their readings. When the stove quits, one of those links has usually failed or tripped. A pellet stove is rarer in Brea than a gas fireplace, but owners who have one tend to use it hard, and hard use finds the weak link.
The faults follow a pattern. The stove will not start: often a burned-out igniter, a burn pot clogged with clinker, or a vacuum switch reading wrong because the vent is partly blocked with fly ash. The fire starts and then dies: the auger may be jammed by a long pellet or sawdust, or the hopper lid switch may be telling the board the lid is open. The stove burns but smokes the glass or smells: the exhaust path needs cleaning, or the door gasket has gone flat. The room fan roars or squeals: its bearings are worn. Each one has a test. We read the code on the display if there is one, put a meter on the suspect part, and look at the vent from end to end. Only then do we say which part has failed and what replacing it involves.
Cleaning, parts and the vent
A lot of pellet stove repairs turn out to be cleaning problems in disguise. Pellets leave a fine light ash that drifts into every cavity of the stove and coats the fan blades, the sensors and the inside of the vent pipe. When the exhaust path narrows, the vacuum switch trips, the board shuts the stove down, and the owner sees an error code. So every repair visit includes clearing the ash from the box, the passages behind the fire, the exhaust fan housing and the vent run. With that done, we can tell whether the original fault is still there. If it is, the part is priced in writing using the maker's part where it is still made or an equivalent listed part where it is not. Old stoves with boards no longer made get a frank note on whether repair is still worth paying for.
The vent deserves its own word. Pellet stoves push their exhaust out under pressure, so any gap at a vent joint pushes fumes out into your living space instead of pulling air inward. We check the joints for sealing, the clearance from the pipe to anything that burns, and the termination outside, which should sit clear of windows, doors and walkways. On a stove vented into an old masonry chimney we look at whether a liner runs to the top, because pellet exhaust dumped into a large cold flue condenses and drafts poorly. If the vent needs work, it sits on the same written quote as the stove. To book, use the contact page and give us the stove brand and model if you have them, what it does when it fails, and any code shown on the display.
How Aubrey Chimney Contractors Works
Price on Paper
You approve a written figure before anything is ordered
Metered Diagnosis
Pilot circuits and gas pressure measured, not guessed
Leak-Tested Joints
Every gas fitting we touch is checked before we leave
Photos and Notes
A record of what we found and what we changed
Where we offer pellet stove repair
Brea, La Habra, Fullerton and Anaheim carry their own pages for this job, with postcodes, homes and weather notes. Search below for any other city.
CA
Pellet Stove Repair in Brea
Up in Olinda Ranch and La Floresta, the newer stucco houses tend to have a gas or factory-built unit, which puts the igniter, gas valve and vent pipe ahead of any brick question. The postwar tracts each have one aging brick chimney, often steel reinforced.
Open this cityCA
Pellet Stove Repair in La Habra
With 77% of the housing dating from before 1980, a typical fireplace is a brick or block box in a one-story ranch. If gas logs were set into it later, our visit covers pilot, valve, and the clamp holding the damper open.
Open this cityCA
Pellet Stove Repair in Fullerton
Brick chimneys from the early 1900s to the 1930s stand in four preservation zones, College Park and Golden Hill among them, along with Hillcrest Park and Raymond Hills. A gas log install in a firebox of that age begins with flue, damper and gas line entry.
Open this cityCA
Pellet Stove Repair in Anaheim
From about the 1970s, many tracts here got factory-built metal fireboxes, and in those the metal flue, cap and gas valve wear on their own schedule. Older homes preserved in the Anaheim Colony Historic District are a separate case, so we identify the firebox type before touching the pilot.
Open this cityRelated Jobs
Chimney Sweep
Soot, creosote and nesting debris cleared from wood and gas flues, so exhaust can climb out the way the appliance expects.
Open →Chimney Inspection
Level 1 or Level 2 under NFPA 211, read with gas appliances in mind: vent size, connector, termination and clearances.
Open →Chimney Repair
Brick, mortar, crown, liner and firebox repairs, planned around any gas line or vent that shares the chimney.
Open →Fireplace Inspection
Firebox, hearth, glass front, valve compartment and surround checked for heat wear, gas odor, tired gaskets and tight clearances.
Open →Fireplace Repair
Cracked firebrick, worn refractory panels, sticking dampers and dropped hearths repaired, on masonry and factory-built fireplaces alike.
Open →Chimney Level 2 Inspection
Video through each flue plus the attic and roof run, for a sale, a switch to gas, or after a chimney fire or quake.
Open →Chimney Cap Installation
Caps with spark screen fitted over one flue or several, and listed tops on factory-built gas vents replaced with the matching part.
Open →Chimney Flashing Repair
Step and counter flashing renewed where the roof meets the chimney or a gas vent pipe, with a cricket where water pools.
Open →Chimney Masonry Repair
Spalled brick replaced and open joints repacked with a mix that matches the brick, before water and heat do more harm.
Open →Chimney Rebuilds
Chimney tops rebuilt from solid brick upward, or replaced with a framed chase and metal vent that suits a gas appliance.
Open →Fireplace Cleaning
Ash, soot and glass film removed from wood and gas fireplaces, with doors, screens and the hearth face cleaned and the room kept covered.
Open →Gas Fireplace Cleaning
Burner ports, pilot hood, logs and the inside of the glass cleaned, so the flame sits blue at its base and the glass clears.
Open →Gas Fireplace Repair
Pilots that drop out, igniters that spark without lighting, weak thermocouples, failed valves and dead remotes traced with a meter and fixed.
Open →Fireplace Remodel
New mantels, surrounds and hearths fitted around wood or gas fireboxes, with distances to the opening kept within the unit's listing.
Open →Fireplace Inserts
Gas inserts set into an existing firebox with their own vent to the top, sized for the room and the opening.
Open →Wood Stove Repair
Door gaskets, baffles, firebrick, glass and air controls on wood stoves renewed, with the stovepipe and clearances checked.
Open →Gas Logs
Gas log sets fitted in a wood fireplace, with the burner size, flue and room checked before the line is run.
Open →Chimney Seismic Retrofit
Old brick stacks braced, strapped to the framing or cut down under a light chase, so a quake is less likely to drop them.
Open →Chimney Crown Repair
Cracked or crumbling crowns sealed or reformed with pitch and an overhang, so rain sheds away from the brick below.
Open →Dryer Vent Cleaning
Lint packed in dryer ducts cleared from the outside hood back to the machine, so the dryer runs cooler and finishes loads sooner.
Open →Chimney Liner Installation
Stainless liners sized for the gas or wood appliance they serve, run inside a flue whose clay tile is cracked or oversized.
Open →Chimney Leak Repair
Water coming in at the chimney traced to the crown, cap, flashing, brick or vent boot, then stopped at that source.
Open →Chimney Waterproofing
A breathable repellent applied to sound brick, so less rain soaks in while damp inside the wall can still dry out.
Open →Chimney Damper Repair
Throat dampers that stick, warp or never seal freed or replaced, or a top-sealing unit fitted with a pull cable.
Open →Chimney Chase Cover
Rusted or sagging steel lids on framed chimneys replaced with a custom pitched lid and a fresh seal at the vent pipe.
Open →