Aubrey Chimney Contractors

Plan the Face Around the Fire, Not the Other Way Round

What Is the Fireplace Doing?

Scope of the Job

Changing the face of a fireplace means working inside the distances the firebox maker allows. A gas unit lists how close a mantel can sit and what the surround may be made of; a masonry opening has code distances. We plan the stone, tile or wood around those numbers, fix the firebox or flue first if needed, and give you the scope and price in writing before demolition.

Stone, tile or plaster faces
Mantels fixed to the framing
Raised or flush hearths built
Clearances held to the unit's listing
Firebox repairs done before the new face

Start with what will burn in it

Most remodels we plan in Brea begin with an owner pointing at a dated brick or tile wall and end with a gas appliance inside it. That order of thinking causes trouble. The appliance sets the rules for everything around it: how big the opening must be, how far combustible trim has to stay from the glass, whether a mantel can go at a given height, what the hearth in front needs to be made of, and where the vent runs. A gas insert slid into the old firebox keeps the existing chimney as its vent path with a liner. A vented log set keeps the open look but needs the damper held open. A direct vent unit can go in a brand new spot on an outside wall, with its own pipe through the wall, and leaves the old fireplace free to be closed off or kept as a feature. Choosing among these first saves redrawing the wall later.

Prices follow the same split. Sliding a sealed gas unit into today's firebox carries a list price of $2,750 to $5,500 fitted. Framing a wall-vented unit somewhere the house never had a fire costs $4,400 to $8,800, since it adds framing, venting and a new gas run. The face of the fireplace, the mantel and the hearth are separate line items, because their cost depends entirely on what you choose: a skim of plaster over brick is a small job, while stacked stone to the ceiling is a large one. Your written quote sets the appliance and the finish work side by side, so you can trade one off against the other. We also tell you what the chimney needs before an insert goes in; a cracked flue or a missing cap is better found before new stone goes on the wall in front of it.

The finish work, and the rules behind it

Once the appliance is chosen, the face can be anything that is non-combustible where the heat reaches it. Tile, stone veneer, plaster, steel panels and painted brick are the usual choices on houses in Fullerton and La Habra. We work out the zones with you: the area right around the opening that must be non-combustible, the band above it where a wood mantel can sit only so close, and the floor in front where the hearth extension protects the flooring. Each appliance maker publishes these distances for their unit, and the building department checks them on a permitted job. Getting them right at the drawing stage avoids the common remodel failure, a beautiful wood mantel that has to come down again because it sits a few inches too low over a gas insert.

On the day, the old face is taken down with the room sealed off and the floor protected. Any masonry repairs inside the firebox or the chimney are done while it is open. The appliance goes in, the gas line is run, the vent or liner is fitted, and everything is leak tested and fired before the new face goes on, so nothing gets built in front of a problem. Then the surround, mantel and hearth are finished. Where the job needs a permit, which most gas appliance work does, we say so in the quote and explain what the inspector will look at; our up to code page has more on that. To start a remodel, use the contact page to tell us what the fireplace is now, what you would like, and roughly what you would like to spend.

How Aubrey Chimney Contractors Works

Price on Paper

You approve a written figure before anything is ordered

Metered Diagnosis

Pilot circuits and gas pressure measured, not guessed

Leak-Tested Joints

Every gas fitting we touch is checked before we leave

Photos and Notes

A record of what we found and what we changed

Related Jobs

Chimney Sweep

Soot, creosote and nesting debris cleared from wood and gas flues, so exhaust can climb out the way the appliance expects.

Open →

Chimney Inspection

Level 1 or Level 2 under NFPA 211, read with gas appliances in mind: vent size, connector, termination and clearances.

Open →

Chimney Repair

Brick, mortar, crown, liner and firebox repairs, planned around any gas line or vent that shares the chimney.

Open →

Fireplace Inspection

Firebox, hearth, glass front, valve compartment and surround checked for heat wear, gas odor, tired gaskets and tight clearances.

Open →

Fireplace Repair

Cracked firebrick, worn refractory panels, sticking dampers and dropped hearths repaired, on masonry and factory-built fireplaces alike.

Open →

Chimney Level 2 Inspection

Video through each flue plus the attic and roof run, for a sale, a switch to gas, or after a chimney fire or quake.

Open →

Chimney Cap Installation

Caps with spark screen fitted over one flue or several, and listed tops on factory-built gas vents replaced with the matching part.

Open →

Chimney Flashing Repair

Step and counter flashing renewed where the roof meets the chimney or a gas vent pipe, with a cricket where water pools.

Open →

Chimney Masonry Repair

Spalled brick replaced and open joints repacked with a mix that matches the brick, before water and heat do more harm.

Open →

Chimney Rebuilds

Chimney tops rebuilt from solid brick upward, or replaced with a framed chase and metal vent that suits a gas appliance.

Open →

Fireplace Cleaning

Ash, soot and glass film removed from wood and gas fireplaces, with doors, screens and the hearth face cleaned and the room kept covered.

Open →

Gas Fireplace Cleaning

Burner ports, pilot hood, logs and the inside of the glass cleaned, so the flame sits blue at its base and the glass clears.

Open →

Gas Fireplace Repair

Pilots that drop out, igniters that spark without lighting, weak thermocouples, failed valves and dead remotes traced with a meter and fixed.

Open →

Fireplace Inserts

Gas inserts set into an existing firebox with their own vent to the top, sized for the room and the opening.

Open →

Pellet Stove Repair

Repairs to stoves that burn pellets: a jammed auger, a cold igniter, a noisy fan or a board that throws codes, plus the vent.

Open →

Wood Stove Repair

Door gaskets, baffles, firebrick, glass and air controls on wood stoves renewed, with the stovepipe and clearances checked.

Open →

Gas Logs

Gas log sets fitted in a wood fireplace, with the burner size, flue and room checked before the line is run.

Open →

Chimney Seismic Retrofit

Old brick stacks braced, strapped to the framing or cut down under a light chase, so a quake is less likely to drop them.

Open →

Chimney Crown Repair

Cracked or crumbling crowns sealed or reformed with pitch and an overhang, so rain sheds away from the brick below.

Open →

Dryer Vent Cleaning

Lint packed in dryer ducts cleared from the outside hood back to the machine, so the dryer runs cooler and finishes loads sooner.

Open →

Chimney Liner Installation

Stainless liners sized for the gas or wood appliance they serve, run inside a flue whose clay tile is cracked or oversized.

Open →

Chimney Leak Repair

Water coming in at the chimney traced to the crown, cap, flashing, brick or vent boot, then stopped at that source.

Open →

Chimney Waterproofing

A breathable repellent applied to sound brick, so less rain soaks in while damp inside the wall can still dry out.

Open →

Chimney Damper Repair

Throat dampers that stick, warp or never seal freed or replaced, or a top-sealing unit fitted with a pull cable.

Open →

Chimney Chase Cover

Rusted or sagging steel lids on framed chimneys replaced with a custom pitched lid and a fresh seal at the vent pipe.

Open →