Aubrey Chimney Contractors

A Stove That Seals Is a Stove You Can Control

What Is the Fireplace Doing?

Scope of the Job

We replace the parts that heat uses up: the rope seal on the door and glass, a warped baffle, cracked firebrick, broken glass and an air control that sticks. On catalytic stoves we look at the combustor. Then we check the stovepipe joints, the connection into the chimney and the distance to anything that can burn. Parts are priced before they are ordered.

Door and glass rope renewed
Baffle and firebrick swapped
New heat glass for a cracked front
Sticking air control freed
Stovepipe joints and clearances checked

How a stove loses control of its fire

A wood stove works by starving the fire. The door, the glass and the ash pan are sealed with woven rope gaskets so that the only air reaching the wood comes through the inlets you set with the control lever. Close the lever and the fire slows; open it and the fire picks up. Above the fire a baffle, a steel or ceramic plate, holds the hot gases in the box long enough to burn rather than rush up the pipe. When the gaskets harden and flatten, air leaks in around the door and the lever stops doing much. The stove eats wood fast, runs hotter than you set it, and leaves more creosote in the chimney. A cracked or missing baffle sends heat straight up the flue. Around Brea wood stoves are less common than gas fireplaces, but the ones we do see tend to be older cast iron units: handsome, heavy, and overdue for new seals.

What owners notice is usually one of a few things. The fire will not slow down even with the air closed. A whiff of smoke comes out when the door opens. The glass turns black in an hour. The stove top glows. Or there is a crack you can see in a firebrick, the glass, or the body itself. Most of these come back to seals, the baffle or the firebrick, and all of them are fixable. A crack in a cast iron or steel body is a different matter; small cracks in some places can be repaired, while a crack across a load-bearing part can mean the stove is done. We look at the stove cold, lift out the baffle and bricks, check the inlets and the pipe, and then explain what we found in the order it matters.

The repair and the test burn

Gaskets are replaced with the diameter and density the stove maker specifies, set in high temperature cement in the cleaned channel. Glass is replaced with ceramic glass cut to the frame, never ordinary tempered glass, which cannot take stove heat. Firebricks are swapped one at a time to the original sizes. Baffles and the air tubes above the fire are replaced with the maker's parts where available. The stovepipe, the black or stainless pipe between the stove top and the ceiling or wall, gets its own check: joints should be fastened with screws, the pipe should not sag, and it must keep its distance from walls and ceilings as listed for that pipe. Where the stove vents into a masonry chimney, we look at the connection and whether a liner is needed. Everything is listed on one written quote, with the parts and the labor shown together.

After the repair we light the stove with you, bring it up to temperature and work the air control so you can see it slow the fire down again. Fresh gaskets give off a little smell on the first firing, which is normal. We watch the door seal, the glass and the pipe joints while the stove is hot. If the chimney above has not been swept recently, we suggest a sweep, since a stove that ran too hot or too smoky with bad seals has usually left extra deposits in the flue; a sweep starts from $410. Wood burning in Orange County falls under South Coast AQMD rules, which can restrict burning on poor air days, so we also explain the difference a sealed, well-tuned stove makes to the smoke it puts out. Book through the contact page and tell us the stove's make if you know it.

How Aubrey Chimney Contractors Works

Price on Paper

You approve a written figure before anything is ordered

Metered Diagnosis

Pilot circuits and gas pressure measured, not guessed

Leak-Tested Joints

Every gas fitting we touch is checked before we leave

Photos and Notes

A record of what we found and what we changed

Related Jobs

Chimney Sweep

Soot, creosote and nesting debris cleared from wood and gas flues, so exhaust can climb out the way the appliance expects.

Open →

Chimney Inspection

Level 1 or Level 2 under NFPA 211, read with gas appliances in mind: vent size, connector, termination and clearances.

Open →

Chimney Repair

Brick, mortar, crown, liner and firebox repairs, planned around any gas line or vent that shares the chimney.

Open →

Fireplace Inspection

Firebox, hearth, glass front, valve compartment and surround checked for heat wear, gas odor, tired gaskets and tight clearances.

Open →

Fireplace Repair

Cracked firebrick, worn refractory panels, sticking dampers and dropped hearths repaired, on masonry and factory-built fireplaces alike.

Open →

Chimney Level 2 Inspection

Video through each flue plus the attic and roof run, for a sale, a switch to gas, or after a chimney fire or quake.

Open →

Chimney Cap Installation

Caps with spark screen fitted over one flue or several, and listed tops on factory-built gas vents replaced with the matching part.

Open →

Chimney Flashing Repair

Step and counter flashing renewed where the roof meets the chimney or a gas vent pipe, with a cricket where water pools.

Open →

Chimney Masonry Repair

Spalled brick replaced and open joints repacked with a mix that matches the brick, before water and heat do more harm.

Open →

Chimney Rebuilds

Chimney tops rebuilt from solid brick upward, or replaced with a framed chase and metal vent that suits a gas appliance.

Open →

Fireplace Cleaning

Ash, soot and glass film removed from wood and gas fireplaces, with doors, screens and the hearth face cleaned and the room kept covered.

Open →

Gas Fireplace Cleaning

Burner ports, pilot hood, logs and the inside of the glass cleaned, so the flame sits blue at its base and the glass clears.

Open →

Gas Fireplace Repair

Pilots that drop out, igniters that spark without lighting, weak thermocouples, failed valves and dead remotes traced with a meter and fixed.

Open →

Fireplace Remodel

New mantels, surrounds and hearths fitted around wood or gas fireboxes, with distances to the opening kept within the unit's listing.

Open →

Fireplace Inserts

Gas inserts set into an existing firebox with their own vent to the top, sized for the room and the opening.

Open →

Pellet Stove Repair

Repairs to stoves that burn pellets: a jammed auger, a cold igniter, a noisy fan or a board that throws codes, plus the vent.

Open →

Gas Logs

Gas log sets fitted in a wood fireplace, with the burner size, flue and room checked before the line is run.

Open →

Chimney Seismic Retrofit

Old brick stacks braced, strapped to the framing or cut down under a light chase, so a quake is less likely to drop them.

Open →

Chimney Crown Repair

Cracked or crumbling crowns sealed or reformed with pitch and an overhang, so rain sheds away from the brick below.

Open →

Dryer Vent Cleaning

Lint packed in dryer ducts cleared from the outside hood back to the machine, so the dryer runs cooler and finishes loads sooner.

Open →

Chimney Liner Installation

Stainless liners sized for the gas or wood appliance they serve, run inside a flue whose clay tile is cracked or oversized.

Open →

Chimney Leak Repair

Water coming in at the chimney traced to the crown, cap, flashing, brick or vent boot, then stopped at that source.

Open →

Chimney Waterproofing

A breathable repellent applied to sound brick, so less rain soaks in while damp inside the wall can still dry out.

Open →

Chimney Damper Repair

Throat dampers that stick, warp or never seal freed or replaced, or a top-sealing unit fitted with a pull cable.

Open →

Chimney Chase Cover

Rusted or sagging steel lids on framed chimneys replaced with a custom pitched lid and a fresh seal at the vent pipe.

Open →
Book a Visit